Campus Network Wiring

Basic Information

Our university’s network is managed by the following system.

blockdiag インターネット SINET コアネットワーク 棟内ネットワーク フロアネットワーク 情報コンセント (LAN ポート) 部屋内ネットワーク 学外ネットワーク 情報基盤センター管理部分 利用者管理部分
SINET

This is an academic network that connects our university with other academic institutions and related service providers. It is operated by the National Institute of Informatics. Connection to the Internet is also done via SINET.

Core Network

This is a network that connects the university-wide information system and the intra-building network within each building.

Intra-building network

This is a network that connects the core network to each floor within a building.

Floor network

This is a network installed on each floor. Connect the Intra-building network to the information outlets in each room. Some devices are connected directly to this network without going through an information outlet.

New network wiring

  1. receive an IP address assignment

Request an IP address or subnet assignment from the IP address block administrator. Please check the IP address management table on-campus for the contact information of the IP address block administrator.

If you want to use a global IP address, you will also need to complete the following Global IP Address procedure.

  1. Check the connection point to the floor network (location of information outlets, etc.)

Decide where to connect to the floor network. If you do not know the location, please refer to the list of network equipment managers for each building on campus and contact the person in charge.

  1. Apply for new network wiring

Please apply for network wiring to net-tech@cc.uec.ac.jp with the following information.

氏名:
所属:
UECアカウント:
電話番号(内線等):

配線を希望するネットワークに関する情報
建物:
部屋:
情報コンセントの番号:
接続先(接続する機器のIPアドレス等):
利用開始日:

Note

If you are installing your own network wiring in a laboratory, etc., please attach information (wiring table or connection diagram) that shows the information outlet and equipment to be used when applying for wiring.

Moving The Network

If you wish to use the same network you have been using before, such as due to moving labs, please follow the steps below to change the wiring.

  1. Check the connection point to the floor network (location of information outlets, etc.)

Decide where to connect to the floor network. If you do not know the location, please refer to the list of network equipment managers for each building and contact the person in charge.

  1. Apply for a change in network wiring destination

Please apply for network transfer to net-tech@cc.uec.ac.jp with the following information.

氏名:
所属:
UECアカウント:
電話番号(内線等):

利用中のネットワークに関する情報
建物名:
部屋名:
情報コンセント番号:
終了日:

移動先に関する情報
建物名:
部屋名:
情報コンセント番号:
開始日:

Network Decommissioning

Please discontinue network wiring that is no longer in use as soon as possible.Please apply for network abolition to net-tech@cc.uec.ac.jp with the following information.

氏名:
所属:
UECアカウント:
電話番号(内線等):

廃止予定ネットワークに関する情報
建物名:
部屋名:
情報コンセント番号:
廃止日:

Applying for a Standard Port

Please apply for a standard port to net-tech@cc.uec.ac.jp with the following information.

建物名:
部屋名:

ポート利用責任者(UECアカウント):

ポート管理者(UECアカウント)(1人目):
ポート管理者(UECアカウント)(2人目):
ポート管理者(UECアカウント)(3人目):